Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 71
Filtrar
1.
J Mech Behav Biomed Mater ; 152: 106407, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38277911

RESUMO

OBJECTIVE: To evaluate the effect of a Nisin-based dentin pretreatment solution on microtensile bond strength, antibacterial activity, and matrix metalloproteinase (MMP) activity of the adhesive interface. MATERIALS AND METHODS: 100 human molars were sectioned to expose dentin. The teeth were assigned to five groups (n = 20), according to the dentin pretreatment: 0.5%, 1.0%, or 1.5% Nisin; 0.12% chlorhexidine (positive control), and no solution (negative control), and divided into 2 subgroups: no aging, and thermomechanical aging. Specimens were etched with 37% H3PO4 for 15 s and submitted to the dentin pretreatment. Then, they were bonded with an adhesive (Adper Single Bond 2) and a resin composite for microtensile bond strength (µTBS) evaluation. Antibacterial activity against Streptococcus mutans was qualitatively examined using an agar diffusion test. Anti-MMP activity within hybrid layers was examined using in-situ zymography. Data were analyzed with two-factor ANOVA and post-hoc Tukey's test (α = 0.050). RESULTS: For µTBS, significant differences were identified for the factors "solutions" (p = 0.002), "aging" (p = 0.017), and interaction of the two factors (p = 0.002). In the absence of aging, higher µTBS was observed for the group 0.5% Nisin. In the presence of aging, all groups showed similar µTBS values. All Nisin concentrations were effective in inhibiting the growth of S. mutans. Endogenous MMP activity was more significantly inhibited using 0.5% and 1.0% Nisin (p < 0.050). CONCLUSION: 0.5% and 1.0% Nisin solutions do not adversely affect resin-dentin bond strength and exhibit a potential bactericidal effect against S. mutans. Both concentrations effectively reduce endogenous gelatinolytic activity within the hybrid layer. CLINICAL RELEVANCE: The use of 0.5% and 1.0% Nisin solutions for dentin pretreatment potentially contributes to preserving the adhesive interface, increasing the longevity of composite restorations.


Assuntos
Colagem Dentária , Nisina , Humanos , Nisina/farmacologia , Nisina/análise , Adesivos/análise , Dentina/química , Antibacterianos/farmacologia , Resinas Compostas/química , Resistência à Tração , Adesivos Dentinários/química , Cimentos de Resina/análise , Teste de Materiais
2.
Int J Dent ; 2023: 2182651, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37435112

RESUMO

This study aimed to evaluate Nd:YAG laser, calcium phosphate, and adhesive system effect as different pretreatments in different protocols on dentin permeability (DP) and bond strength (BS). Fifty human dentin discs were used (4 mm in diameter and 1,5 mm in height). Specimens were divided into five groups (n = 10): (A): adhesive system (control); (AL): adhesive system + Nd:YAG laser; (LAL): Nd:YAG laser + adhesive system + Nd:YAG laser; (PAL): calcium phosphate-based dentin desensitizer TeethMate + adhesive system + Nd:YAG laser; and group (PLAL): Nd:YAG laser + calcium phosphate-based dentin desensitizer + adhesive system + Nd:YAG laser. All materials were used according to the manufacturers' instructions. The specimens were submitted to artificial aging (5,000 thermal cycles and 12 × 104 mechanical cycles) then a bond test was performed. DP was measured using the split chamber model. Data were submitted to one-way analysis of variance (ANOVA), paired t-test, RM ANOVA, and Tukey test (p < 0.05). All treatments were effective in DP reduction. For BS, the groups PAL and PLAL had improved BS with a statistically significant difference of the control group (A). Nd:Yag laser irradiation and calcium phosphate-based desensitizing agents significantly reduced DP, and the association between them could improve the BS on resin-human dentin interface.

3.
Eur J Dent ; 2022 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-36513340

RESUMO

OBJECTIVES: This article evaluated the effect of substrates rigidities on the post-fatigue fracture resistance of adhesively cemented simplified restorations in lithium disilicate glass ceramic. METHODS: Precrystalized computer-aided design/computer-aided manufacturing ceramic blocks were processed into disc-shaped specimens (n = 10, Ø = 10 mm), mimicking a simplified restoration at two thicknesses (0.5 and 1.0 mm). Thereafter, the discs were cemented onto different base substrates (dentin analogue [control], dentin analogue with a central core build-up of resin composite [RC], or glass ionomer cement [GIC]). The specimens were subjected to mechanical cycling in a chewing simulator (100 N, 1 × 106 cycles, 4 Hz) and then subjected to thermocycling aging (10,000 cycles, 5/37/55°C, 30 seconds). After the fatigue protocol, the specimens were loaded until failure (N) in a universal testing machine. Finite element analysis calculated the first principal stress at the center of the adhesive interface. RESULTS: The results showed that "restoration thickness," "type of substrate," and their interaction were statistically significant (one-way analysis of variance; p < 0.001). Regardless the restoration thickness a higher fracture load was observed for specimens cemented to dentin analogue. Among the base materials, RC build-up presented the highest fracture load and lower stress magnitude for both restoration thicknesses in comparison with GIC build-up. The 0.5-mm restoration showed higher stress peak and lower fracture load when submitted to the compressive test. CONCLUSION: More flexible base material reduces the fracture load and increases the stress magnitude of adhesively cemented lithium disilicate restorations regardless the ceramic thickness. Therefore, more rigid substrates are suggested to be used to prevent restoration mechanical failures.

4.
Int J Dent ; 2022: 4821021, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36249726

RESUMO

Objective: This study aims to analyze the fluorescence-aided identification technique efficacy on adhesive remnant removal from the enamel surface after orthodontic bracket debonding. Materials and Methods: Forty-five extracted human upper central incisors were divided into 3 groups (n = 15) according to the kind of adhesive for bracket bonding and the use or absence of near UV light for remnant removal: BF/UV- fluorescent adhesive/UV light, BF/0-fluorescent adhesive/no UV light, and TB/0-nonfluorescent adhesive/no UV light. For all teeth, 100% of the adhesive used remained on the enamel surface after debonding. Fifteen dentists performed adhesive removal on the enamel surface using a carbide bur. The specimens were analyzed by a stereomicroscope, and the adhesive remnant percentage from each specimen was calculated. The time used by each dentist to perform the removal was recorded. The data were analyzed by one-way ANOVA and Tukey's test. Results: Significant differences were observed among groups for adhesive remnant (p=0.0008) and for time (p=0.0001). The means of adhesive remnant were BF/UV (5.84), BF/0 (34.37), and TB/0 (37.02). The mean times necessary to remove adhesive were BF/UV (1 min 40 s), BF/0 (3 min 03 s), and TB/0 (2 min 46 s). For the BF/UV group, significantly lower values of adhesive remnants and time for debonding were found (p < 0.05). Conclusion: The fluorescence-aided identification technique significantly reduced the amount of adhesive remnant, and the time necessary to perform this clinical procedure.

5.
Int J Dent ; 2022: 5837864, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35815117

RESUMO

Radiotherapy induces a higher level of Candida spp. colonization, resulting in oral candidiasis. This study aimed to evaluate the phototransformation potential of the glycolic extract of Curcuma longa (C. longa); the antifungal activity of C. longa, curcumin, and antifungal photodynamic therapy (aPDT) with blue light-emitting diodes "LED" on Candida albicans and Candida tropicalis in vitro; and the toxicity of C. longa and curcumin in Galleria mellonella model. In order to confirm the light absorption capacity of the C. longa extract, its phototransformation potential was evaluated. The antifungal effect of C. longa, curcumin, and aPDT was evaluated over Candida spp. Finally, the toxicity of C. longa and curcumin was evaluated on the Galleria mellonella model. The data were analyzed using the GraphPad Prism 5.0 software considering α = 5%. It was found that C. longa, curcumin, and aPDT using blue LED have an antifungal effect over C. albicans and C. tropicalis. The extract of C. longa 100 mg/mL and curcumin 200 µg/mL do not show toxicity on Galleria mellonella model.

6.
Microsc Res Tech ; 85(8): 3014-3024, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35593488

RESUMO

The present study evaluated the bond strength (µTBS) of dentin treated with chlorhexidine and propolis subjected to simulated pulpal pressure (SPP) and thermocycle aging. One hundred and twenty healthy human molars were sectioned to obtain 2 mm of dentin thickness and were divided into two groups (n = 60): SPP (15 cm H2 O) and no SPP (Control group). Dentin surfaces were conditioned with 37% phosphoric acid for 15 s and were divided according to the dentin treatment (n = 20): Control; Chlorhexidine gluconate (0.2% for 30 s) and Propolis (aqueous propolis extract for 30 s). Half of the specimens were submitted to 15,000 thermocycle aging (5 ± 2°C and 55 ± 2°C). The samples were sectioned into beams and submitted to µTBS. Data were analyzed by three-way ANOVA (SPP × Dentin treatment × Thermocycle aging) and the Tukey's tests (p < .001). With regard to the SPP, ANOVA revealed that the Control group (32.98 MPa) had significantly higher values of µTBS when compared to the SPP (29.19 MPa). With regard to Thermocycle aging, no aging (34.05 MPa) had significantly higher values of µTBS when compared to the aging (28.12 MPa). With regard to the dentin treatment, Propolis and Chlorhexidine did not statistically influence the results (p > .05). The SPP and thermocycle aging negatively influenced the bond strength between the dentin and resin; the 0.2% chlorhexidine digluconate and aqueous propolis extract solutions did not interfere in the bond strength between the resin and dentin. The use of chlorhexidine and propolis as a dental treatment may not influence the dentin bond strength, but SPP and thermocycle aging may damage the longitudinal dentin bond strength. RESEARCH HIGHLIGHTS: Chlorhexidine and propolis as a dental treatment may not influence the dentin bond strength. Simulated pulpal pressure and thermocycle aging may damage the longitudinal dentin bond strength.


Assuntos
Colagem Dentária , Própole , Clorexidina/química , Clorexidina/farmacologia , Resinas Compostas/química , Dentina , Adesivos Dentinários/química , Humanos , Teste de Materiais , Cimentos de Resina/química , Resistência à Tração
7.
Int J Dent ; 2022: 5771341, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35265134

RESUMO

Objective: To evaluate the physicochemical (sorption (SOR), solubility (SOL), and degree of conversion (DC)) and mechanical (flexural strength (FS), modulus of elasticity (ME), and compressive strength (CS)) properties of adhesives with different water contents (D2O). Materials and Methods: An adhesive was formulated: 55 wt% BisGMA, 45 wt% HEMA, 0.5 wt% camphorquinone, 0.5 wt% EDMAB, and 1.0 wt% DPIHP. D2O was added into the adhesives (0 wt%, 10 wt%, and 16 wt%). DC was monitored through the FTIR. FS, ME, CS, SOR, and SOL were tested. The adhesive samples were aged in deionized water, ethanol, and acetone. Data were submitted to ANOVA and Tukey's tests (5%). Results: For DC, the 0 wt% group showed a significant reduction (68.09 ± 0.14A) compared with the 10 wt% (87.07 ± 0.81B) and 16 wt% groups (89.87 ± 0.24B); 10 wt% showed the highest FS (MPa) mean values (141.6 ± 6.71B) compared with the 0 wt% (109.4 ± 20.5A) and 16 wt% (107.8 ± 15.8A). For the CS (MPa) and ME (GPa), the 16 wt% showed the lowest mean values (98.8 ± 18.0B and 2.2 ± 0.3B, respectively) compared with the 10 wt% and 0 wt%. For the SOR, 16 wt% of water showed the highest mean values and the ethanol showed the lowest mean values of SOL regardless of water content. Conclusion: The amount of water content and the types of aging solvents significantly affect the adhesive properties.

8.
Int J Dent ; 2021: 2935507, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34956366

RESUMO

This study compared the bond strength of a composite repair made with a bulk fill composite and a conventional one using different surface treatments. Specimens were prepared as truncated cones (bases: 4 mm × 2 mm, height: 4 mm) using a bulk fill (OBFa: Filtek One) or a conventional resin (FTKa: Filtek Z250) (n = 66). They were artificially aged (10,000 cycles, 5°C-55°C, 30 sec) and subdivided according to surface treatments: NT-no treatment (control), Abr-abrasion with a diamond tip, and sand-sandblasting with aluminum oxide (50 µm). Treatments were performed over the smaller diameter surface, followed by adhesive (Scothbond Universal) application. A new specimen with similar dimensions was constructed over it using either the OBF or the FTK, totaling 12 groups (n = 11). Bond strength was assessed by tensile test. The data were submitted to two-way ANOVA separately for OBFa and FTKa, followed by Tukey's test (p < 0.05). For the aged OBFa groups, there was significant differences for composite type and surface treatment, with higher values of bond strength when repaired with the same material (OBFa/OBF > OBFa/FTK), and sandblasting and bur abrasion presented higher values compared to the control group (NT). For the aged FTKa groups, there were no differences for the composite or surface treatment. Therefore, the bulk fill resin composite tested present better repair performance when the same composite was used, while the conventional resin composite was less influenced by the material and the surface treatment performed.

9.
Int J Dent ; 2021: 3130813, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34745262

RESUMO

This study aimed to evaluate the efficacy of passive ultrasonic irrigation (PUI) on dissolving the organic tissue inside simulated internal root resorption (IRR) using sodium hypochlorite (NaOCl) or chlorhexidine (CHX). A total of 40 human lower premolars were collected based on dimensional and morphological similarities. The roots were embedded in cylinders (3 cm diameter; 2.5 cm height) of self-cured acrylic resin, and then an IRR was simulated. The specimens were divided into 4 groups (n = 10) according to irrigation protocols: group 1: CHX + PUI; group 2: CHX; group 3: NaOCl + PUI; group 4: NaOCl. The total irrigation time was 150 s at a flow rate of 5 mL/min. A tissue mass of porcine palatine mucosa was used to simulate the organic tissue, it was weighed before and after the irrigation using an analytic balance, and the difference between both readings was calculated and transferred to percentage values. Data were submitted to statistical analysis using two-way ANOVA (factors: irrigant type and with/without PUI) and Tukey's test for multiple comparisons among the experimental groups (α = 0.05). There was a significant difference in both factors (irrigant: p=0.04; PUI: p ≤ 0.001). The groups that used PUI were more effective in dissolving the organic tissue of the IRR simulation than the groups without PUI. PUI is more effective than the syringe and needle irrigation in organic tissue dissolution.

10.
J Clin Exp Dent ; 13(4): e357-e362, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33841734

RESUMO

BACKGROUND: This study aimed to evaluate surface treatments, adhesives and composites for repairing silorane based restorations. MATERIAL AND METHODS: One hundred and twenty truncated cones (2 mm smaller diameter and 4 mm larger diameter) made of silorane composite were divided in 12 groups according with the surface treatment (diamond bur and oxide aluminum abrasion), the adhesive (Adper Scothbond Multipurpose (3M ESPE), Ecusit (Voco) and Filtek P90 Adhesive (3M ESPE)). Each group was subdivided in two according with the composite used for repair (methacrylate and silorane). The repair was made with a second truncated cone build over the first one and bond strength assssed by tensile strength. Data were submitted to ANOVA 3-way and Tukey's test (p<0.05). RESULTS: There was difference only for the adhesives and the composites, with conventional adhesives (Adper Scothbond Mutipurpose) and methacrylate-based composites (Filtek Z350) presenting superior tensile strength compared to the silorane ones (P90 Adhesive system and composite). CONCLUSIONS: Therefore, it must be concluded that silorane composite can be repaired with methacrylate base composites and adhesives. Key words:Silorane composites, composites, bond strength, minimal intervention.

11.
Int J Dent ; 2021: 6677159, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33815502

RESUMO

This study evaluated the effect of different surface treatments on the tensile bond strength between lithium disilicate glass-ceramics, resin cement, and dentin. Fifty truncated cone-shape glass-ceramics were divided into five groups (n = 10): G1, control: 10% hydrofluoric acid (HF); G2, Nd:YAG laser + silane; G3, Sil + Nd:YAG laser; G4, graphite + Nd:YAG laser + Sil; and G5, graphite + Sil + Nd:YAG laser. Fifty human third-molars were cut to cylindrical shape and polished to standardize the bonding surfaces. The glass-ceramic specimens were bonded to dentin with a dual-cured resin cement and stored in distilled water for 24 h at 37ºC. Tensile testing was performed on a universal testing machine (10 Kgf load cell at 1 mm/min) until failure. The bond strength values (mean ± SD) in MPa were G1 (9.4 ± 2.3), G2 (9.7 ± 2.0), G3 (6.7 ± 1.9), G4 (4.6 ± 1.1), and G5 (1.2 ± 0.3). Nd:YAG laser and HF improve the bond strength between lithium disilicate glass-ceramics, resin cement, and dentin. The application of a graphite layer prior to Nd:YAG laser irradiation negatively affects this bonding and presented inferior results.

12.
Int J Dent ; 2020: 6677588, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33376491

RESUMO

Root perforation is a common endodontic accident. Its management depends mainly on root canal disinfection and sealing the perforation area by preventing any communication with the periodontium to prevent recontamination. A patient was referred to treat root perforation due to a previous treatment of tooth #22. The diagnosis was symptomatic periapical periodontitis, and the treatment plan was to retreat the root canal of #22 and make a surgical intervention (apicoectomy) associated with antimicrobial photodynamic therapy as a complementary technique. Five mineral oxides (5MO) cement was used as a root-end filling material. The procedures were performed in two sessions and controlled in two visits (after 30 days and 12 months). A bone neoformation was observed at the periapical area of tooth #22. 5MO bioceramic cement was effective in inducing the repair of the periapical lesion and had the ability to seal the exposed periapical area of the tooth. Its success depended mainly on root canal and surgical site disinfection.

13.
Heliyon ; 6(5): e03925, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32420491

RESUMO

OBJECTIVES: The present study examined a technique for reducing dentin permeability through the application of a calcium phosphate (CaP)-based desensitiser with a laser-assisted process and evaluated adhesive-dentin bond strength. Methods: Thirty dentin discs were divided into two groups according to whether the selected desensitiser (TeethMate; Kuraray Noritake) was used prior to dentin bonding. Each group was subdivided into three subgroups (n = 5): A- Adhesive (Single Bond Universal, 3M ESPE), AL- Adhesive + Laser (Nd:YAG 60 mJ) and LAL- Laser + Adhesive + Laser. Dentin permeability values (%) were recorded before and after desensitiser application. Resin composites were placed over the bonded specimens; the latter were aged prior to microtensile bond strength evaluation. Gelatinolytic activity within the hybrid layers was examined with in-situ zymography using confocal laser scanning microscopy. Data were analysed with ANOVA and Tukey test (α = 0.05). RESULTS: Significant differences in dentin permeability were identified for all groups (p = 0.00). Both laser treatment (p = 0.182) and desensitiser application (p = 0.687) did not significantly improve dentin bond strength. Ultrastructure of the resin-dentin interface identified presence of calcium phosphate within dentinal tubules. Laser treatment did not affect hybrid layer ultrastructure. Both treatment modalities (intratubular CaP occlusion and laser) had no influence on gelatinolytic activity within hybrid layers. CONCLUSION: Although intratubular CaP occlusion and laser treatment were effective in reducing dentin permeability, they did not affect bond strength, interfacial ultrastructure and gelatinolytic activity within hybrid layers. CLINICAL RELEVANCE: Treatment of etched dentin with Nd:YAG Laser at 60 mJ does not adversely affect collagen ultrastructure and gelatinolytic activity within the hybrid layer. The application of a calcium phosphate-based desensitiser to etch dentin does not affect dentin bond strength.

14.
J Clin Exp Dent ; 12(3): e277-e284, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32190199

RESUMO

BACKGROUND: Teeth with internal root resorption (IRR) have guarded prognosis, considering that IRR defect could influence on the post bond strength. The aim of this study was to evaluate the bond strength and the bond interface between different glass fiber-reinforced posts (FRP) after cementation in teeth with simulated internal root resorption (IRR). MATERIAL AND METHODS: Forty-five (45) human premolar roots with simulated IRR were embedded in acrylic resin blocks and cross-sectioned into two segments, enabling them to be re-approximated by screws. Intracanal medication was inserted for 15-days, removed by passive ultrasonic irrigation (PUI) and examined by stereomicroscopy. The push-out bond strength of two fiber reinforced composite posts (Rebilda Post - RP) and Rebilda Post GT - GT, (VOCO) were evaluated at the cervical and IRR regions (n = 20). And, the bonded interface between resin cement and root dentine was analysed by scanning electron microscopy (SEM). RESULTS: 62.5% of IRR were not completely cleaned by PUI. Bond strength values at the cervical region (9.8 and 14.6 MPa) were higher than the IRR region (6.3 and 4.2 MPa). Micrographies showed bubbles in the cement and spaces in the bonded interface. CONCLUSIONS: RP post showed better bond strength at the cervical region while GT had better bond strength at the IRR region. Key words:Endodontics, root canal filling materials, root resorption, X-Ray microtomography.

15.
F1000Res ; 8: 1743, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31723426

RESUMO

Background: The purpose of this study was to evaluate the effect of different bonding agents on bond-strength to demineralized enamel after remineralizing treatments and resin infiltration. Methods: Buccal enamel of 120 bovine incisors was polished and then were divided into five experimental groups: SE (sound enamel); DE (demineralized enamel); AS (demineralized enamel immersed in artificial saliva for eight weeks); NaF (demineralized enamel treated with 0.05% sodium fluoride solution (one minute) for eight weeks); Ic (demineralized enamel infiltrated with a low-viscosity resin (Icon-DGM). These groups were subdivided according to adhesive system used: self-etching adhesive Adper Easy One (3M/ESPE) and etch-and-rinse adhesive Single Bond (3M/ESPE). The composite resin blocks were fabricated using a Teflon matrix. A thermomechanical cycling machine was used to carry out the artificial aging of the specimens and thus were sectioned into sticks. The microtensile tests were performed using a universal testing machine at a cross-head speed of 1 mm/min. Data (in MPa) were subjected to two-way ANOVA and Tukey's tests (5%). Results: Significant differences were found for both factors tested and interactions (p<0.05). Tukey's test results of µTBS (mean ± SD) were: etch-and-rinse SE (28.79±3.93); DE (30.41±7.22); AS (29.03±3.33); NaF (29.81±4.06)a; Ic (29.47±5.5);  and self-etching SE (30.37±6.96); DE (14.62±4.47); AS (9.79±2.32); NaF (9.36±2.31); Ic (30.78±8.68).   Conclusions: Resin infiltration did not affect the bond strength of demineralized enamel for both adhesive systems tested. For etch-and-rinse adhesive, no differences were observed for the tested groups. For self-etching adhesive, only the resin-infiltrated group showed similar bond strength to sound enamel. Both etch-and-rinse and self-etching adhesive systems can be used in resin-infiltrated enamel, if a composite restoration needs to be further performed. In enamel that has undergone the de/remineralization process, the use of a total-etch adhesive might be preferable for the restorative procedure.


Assuntos
Condicionamento Ácido do Dente , Adesivos , Animais , Bovinos , Resinas Compostas , Teste de Materiais
16.
Am J Dent ; 31(6): 303-308, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30658376

RESUMO

PURPOSE: To investigate the effects of whitening toothpastes over the wear and surface roughness of ormocer and methacrylate composites. METHODS: Cylindrical specimens (n=120) were prepared using methacrylate-based composites (Filtek Z350 XT, TPH3 and GrandioSO) and a pure-ormocer composite (Admira Fusion). Brushing abrasion (100,000 strokes) was performed using whitening toothpastes containing different abrasives: alumina (Colgate Ultrawhite), perlite (CloseUp Whitening) and sodium bicarbonate (Kin Progressive Whitening). Wear and roughness alteration were evaluated. Additional analyses of microhardness, degree of conversion and scanning electron microscopy were also performed. RESULTS: Data were separately analyzed with Kruskal-Wallis and ANOVA tests. Statistically significant differences were found for the composites and whitening toothpastes (P<0.05). For all toothpastes, GrandioSO showed lower wear than Z350 XT and Admira Fusion, although non-significant differences in relation to TPH3 were observed. For perlite and bicarbonate-based toothpastes, Z350 XT, Admira Fusion and TPH3 did not present significant differences among them for wear. For alumina-based toothpaste, Z350 XT showed higher wear than TPH3, while Admira Fusion showed intermediate values. Higher wear and roughness alteration were observed after using alumina-containing toothpaste. All composites tested showed increased roughness after brushing. Z350 XT presented the lowest roughness alteration, while Admira Fusion the highest. CLINICAL SIGNIFICANCE: The alumina-containing whitening toothpaste significantly increased the wear and roughness of composites in relation to the other abrasives tested. However, using the ADA standards, the wear promoted by all whitening toothpastes tested would be considered clinically acceptable for all materials. The type of organic matrix in a composite is not the main factor that determines the wear rate, but also its interaction with the inorganic fillers and the filler content. The composite GrandioSO showed the lowest overall wear values, while Z350 XT resulted in the smoothest surfaces.


Assuntos
Metacrilatos , Cerâmicas Modificadas Organicamente , Cremes Dentais , Teste de Materiais , Propriedades de Superfície , Escovação Dentária
17.
Acta Biomater Odontol Scand ; 3(1): 1-7, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28642926

RESUMO

Objective: This study evaluated the effect of food-simulating media associated with brushing and coffee staining on color stability of different composite resins. Materials and methods: Eighty specimens were prepared for each composite: Grandio SO (Voco), Amaris (Voco), Filtek Z350XT (3M/ESPE), Filtek P90 (3M/ESPE). They were divided into four groups according to food-simulating media for 7 days: artificial saliva (control), heptane, citric acid and ethanol. The composite surface was submitted to 10,950 brushing cycles (200 g load) in an automatic toothbrushing machine. The specimens were darkened with coffee solution at 37 °C for 24 h. After each treatment, color measurements were assessed by spectrophotometry, using CIE L*a*b* system. The overall color change (ΔE) was determined for each specimen at baseline (C1) and after the treatments (food-simulating media immersion/C2, brushing/C3 and dye solution/C4). Data were analyzed by two-way repeated measures ANOVA and Tukey's tests (p < .05). Results: The results of RM-ANOVA showed significant differences for composites (p = .001), time (p = .001) and chemical degradation (p = .002). The mean of ΔE for composites were: Z350XT (5.39)a, Amaris (3.89)b, Grandio (3.75)bc, P90 (3.36)c. According to food-simulating media: heptane (4.41)a, citric acid (4.24)a, ethanol (4.02)ab, artificial saliva (3.76)b. For the treatments: dye solution (4.53)a, brushing (4.26)a, after food-simulating media (3.52)b. Conclusions: The composite resin Filtek Z350XT showed significantly higher staining than all other composite resin tested. The immersion in heptane and citric acid produced the highest color alteration than other food-simulating media. The exposure of samples to brushing protocols and darkening in coffee solution resulted in significant color alteration of the composite resins.

18.
J Adhes Dent ; 19(2): 121-127, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28439576

RESUMO

PURPOSE: To evaluate the influence of previous acid etching on the bond strength of a self-etch universal adhesive system on sound and eroded enamel and dentin. MATERIALS AND METHODS: Flat enamel and dentin surfaces were obtained from bovine incisors (n = 44) and divided into two groups according to the exposure to erosive conditions: sound (without erosion) and eroded (after erosive challenge with 0.3% citric acid, pH 2.6, 5 min, 4x/day, 5 days). Each group was then divided into two subgroups (n = 11) according to the application or not of 37% phosphoric acid before applying a universal self-etch adhesive. Single Bond universal adhesive (3M ESPE) was applied and composite blocks were built up using Amelogen Plus (Ultradent). Sticks (1 × 1 mm) were obtained and the microtensile bond strength (µTBS) was assessed using a universal testing machine at a speed of 1 mm/min. Data were analyzed with two-way ANOVA and Tukey's tests (p < 0.05). RESULTS: For enamel groups, significant differences were observed for erosive challenge (p = 0.034) and acid etching (p = 0.047), but not for the interaction between them (p = 0.182). The means ±â€¯SD (MPa) for the erosive conditions were: sound, 25.02 ±â€¯5.82a; eroded, 28.45 ±â€¯5.92b; and for acid etching: without, 24.89 ±â€¯5.39a; with, 28.58 ±â€¯6.23b (different superscript letters indicate significant differences). For dentin, both the erosive condition (p = 0.936) and acid pretreatment (p = 0.084), as well as their interaction (p = 0.107), did not affect the bond strength. CONCLUSION: The erosive challenge and previous acid etching significantly increased the bond strength of the tested universal adhesive to enamel but not to dentin.


Assuntos
Condicionamento Ácido do Dente , Colagem Dentária , Animais , Bovinos , Resinas Compostas , Cimentos Dentários , Esmalte Dentário , Dentina , Adesivos Dentinários , Teste de Materiais , Cimentos de Resina , Resistência à Tração
19.
Artigo em Inglês | MEDLINE | ID: mdl-27977829

RESUMO

This study evaluated the influence of liner agents placed under resin composite restorations on shear bond strength (SBS) to dentin. A total of 40 extracted bovine incisors were used. Enamel surfaces were ground to expose a flat dentin area of 7 mm in diameter. Teeth were divided into four groups according to tested liners: Group 1 (control) used no liner; Group 2 used a resin-modified glass-ionomer cement liner (Vitrebond Plus, 3M ESPE); Group 3 used a light-activated calcium hydroxide resin liner (Ultra-Blend Plus, Ultradent); and Group 4 used a polyacrylic acid surface treatment + conventional glass-ionomer cement liner (Vidrion F, SSWhite). All groups were subjected to bonding procedures with Single Bond (3M ESPE) and 4-mm-thick buildups of resin composite were fabricated. Artificial aging was performed, and the specimens were submitted to mechanical shear testing. One-way analysis of variance (ANOVA) revealed significant differences among liners (P = .00). Group 4 showed the highest SBS. Group 1 showed significantly higher mean SBS compared with Group 3. Results showed that SBS is improved when using polyacrylic acid surface treatment + conventional glass-ionomer cement and decreased when using light-activated calcium hydroxide when compared with no liner. Polyacrylic acid surface treatment + conventional glass-ionomer cement as a liner placed under adhesion surface can improve the shear bond strength between dentin and resin, while light-activated calcium hydroxide resin should be used restrictedly in very deep cavities, because they may reduce the bond strength of the restoration submitted to masticatory forces and temperature changes in the oral environment.


Assuntos
Resinas Compostas/química , Forramento da Cavidade Dentária/métodos , Restauração Dentária Permanente/métodos , Animais , Bis-Fenol A-Glicidil Metacrilato , Bovinos , Análise do Estresse Dentário , Cimentos de Ionômeros de Vidro , Técnicas In Vitro , Teste de Materiais , Compostos Orgânicos , Resistência ao Cisalhamento , Propriedades de Superfície
20.
Braz. dent. sci ; 20(1): 17-24, 2017. tab, ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-836660

RESUMO

Objetivo: Este estudo avaliou o efeito da solução de gluconato de clorexidina 0,2% (CHX) usado como primer terapêutico sobre a resistência de união longitudinal de adesivo convencional a dentina. Material e Métodos: dentes bovinos foram desgastados para obter uma área de dentina, e foram divididos em 2 grupos: Grupo C (Controle) - ácido fosfórico à 37%) + 0,2% CHX por 30s + Single Bond. Blocos de resina composta form fabricados e armazenados por 24 h e 6 meses, seccionados e submetidos ao teste de resistência a microtração. Os resultados foram analisados por ANOVA dois-fatores seguido pelo teste de Tukey. Resultados: Valores de média (±Desvio-padrão) (MPa): Grupo CHX/24h - 41,8(±2,62)A; Grupo C/24h - 40,8(±3,35)AB; Grupo CHX/6 meses ­ 36,4(±3,52)B; Grupo CHX/6 meses - 26,1(±1,54) C. Resultados: Valores de média (±Desvio-padrão) (MPa): CHX (24 h) ­ 41,76 (±2,62)a; C (24h) ­ 40,81 (±3,35)ab; GT (24h): 37,38(2,98)abc; CHX (6 meses) ­ 36,04 (±3,52) bcd; EGCG (24h) ­ 35,91 (±4,82)cd; EGCG (6 meses) ­ 35,75 (±4,44)cd; GT (6 meses) ­ 31,95 (±3,40)de; C (6 meses): 30,05 (±1,54)e. Conclusão: CHX aumentou a resistência de união imediata da interface dentina-resina e significantemente reduziu a perda de resistência de união após 6 meses de armazenagem em água quando comparado ao grupo controle.(AU)


Objective: This study evaluated the effect of 0.2% chlorhexidine gluconate solution used as an therapeutic primer on the long-term bond strength of etch-and-rinse adhesive to dentin. Material and Methods: Bovine incisors were worn to expose an area of dentin and were divided into 2 groups: Group C (Control) - acid etching with 37% phosphoric acid + Single Bond; Group CHX (0.2% CHX) - acid etching with 37% phosphoric acid + 0.2% CHX for 30 s + Single Bond. Blocks of composite were fabricated and stored for 24 h or 6 months, sectioned into beams and submitted to microtensile tests. Results were analyzed by two-way ANOVA and Tukey tests. Results: Mean (±SD) values (in MPa) were as follow: Group CHX/24h - 41.8(±2.62)A; Group C/24h - 40.8(±3.35)AB; Group CHX/6 months ­ 36.4(±3.52)B; Group CHX/6 months - 26.1(±1.54)C. Conclusion: CHX improve the imediatte bond strength of resin-dentin and significantly lowered the loss of bond strength after 6 months water storage as seen in the control bonds.(AU)


Assuntos
Animais , Bovinos , Clorexidina , Resinas Compostas , Dentina , Adesivos Dentinários
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...